Quick answer: Most Grundfos SCALA1 and SCALA2 problems are caused by the water supply, plumbing, installation or settings, not a defective pump. Before you return your pump, check the power, make sure the water supply is on and all valves are open, prime the pump, clean the inlet filter or strainer, and look for leaks. Take a photo of the indicator lights before you press Reset, then contact Fresh Water Systems if the problem continues.

If your SCALA pump isn't working the way you expect, don't box it up just yet. A red light, a pump that keeps cycling or weak water pressure can often be fixed in a few minutes. This guide walks you through the most common SCALA1 and SCALA2 issues and what to check first.

⚠️ Safety first: Switch off and unplug the pump before touching fittings, valves or the priming plug. Never open the motor or electrical enclosure. If you feel a shock or tingling from the pump or plumbing, stop using it and contact a qualified electrician.

Identify your pump

The SCALA1 and SCALA2 have different controls and troubleshooting steps, so start by confirming which model you have. Use the model name and voltage on the pump nameplate when contacting support.

Feature SCALA1 SCALA2
Control panel Start/Stop, Bluetooth/app connection, Reset and status/alarm indicators On/off control, up/down pressure buttons, Reset, pressure lights and alarm indicators
Built-in pressure tank No Yes; air valve on top
Pressure control Fixed-speed pump; app offers monitoring/control features and setup options depending on configuration Adjustable pressure setpoint; factory setting is about 44 psi
Diagram comparing the Grundfos SCALA1 and SCALA2 control panels, buttons and alarm symbols

SCALA1 and SCALA2 control panels side by side

Grundfos SCALA1 booster pump control panel with Start/Stop, Bluetooth and Reset buttons

SCALA1

Grundfos SCALA2 booster pump control panel with pressure buttons, Reset and alarm indicators

SCALA2

Find your model and voltage on the nameplate:

Grundfos SCALA1 nameplate showing model, voltage and part number

SCALA1 nameplate

Grundfos SCALA2 nameplate showing model, voltage and part number

SCALA2 nameplate

Start with these quick checks

  • Power: Check that the outlet works and that the breaker or GFCI¹ has not tripped. Compare the outlet supply with the voltage printed on the pump nameplate. Do not use a damaged cord, plug or outlet.
  • Water supply: Make sure the water source has water and all inlet and outlet shutoff valves are open.
  • Priming: The pump housing must be filled with water before first start-up. If drawing from a tank or well below the pump, fill through the priming port with about 1.7 L (0.45 gal) of clean water. If connected to a pressurized supply, open the supply valve and allow the housing to fill. Follow the manual for your exact model and installation.
  • Air in the pipes: Open a tap at the highest point and let it run until water flows steadily without sputtering.
  • Filters and strainers: Check for a clogged inlet strainer or sediment filter. A restricted inlet can cause low flow, noise, alarms or poor pressure.
  • Hidden water use: Close all taps and check toilets, ice makers, irrigation, water treatment equipment and other fixtures for leaks or automatic cycles.
  • Connections: Look for water at the pipe connections. Pump unions with flat gaskets should be correctly seated and hand-tightened; overtightening with a wrench can damage connections. Use appropriate sealant only where the connection type calls for it.
  • Record the indicator lights: Take a photo of the panel before resetting the pump. The light pattern helps identify the cause.

Find the symptom that matches yours

The pump appears completely dead

  • Try an outlet you know works, and check the breaker/GFCI¹. Avoid extension cords and power strips during testing.
  • Check that the pump voltage on the nameplate matches the supply.
  • If the panel is lit but the pump is not running, open a tap: the pump may simply be idle because there is no demand.
  • SCALA1: Check that it has not been stopped at the panel or through an app schedule/external control, if used. SCALA2: Check whether the panel is locked or the pump has been stopped manually; consult the model manual for the correct button sequence.
  • If there is no indicator light on a confirmed working, correctly rated supply, or a breaker trips repeatedly, stop and contact support. Do not repeatedly reset a tripping circuit.
Grundfos SCALA2 control panel with yellow padlock showing the panel is locked

SCALA2 panel locked: hold both pressure arrows for 3 seconds to unlock

Grundfos SCALA2 control panel with yellow Stop indicator showing a manual stop

SCALA2 manually stopped: press On/Off to restart

Grundfos SCALA1 control panel with yellow Stop indicator showing a manual stop

SCALA1 manually stopped: press Start/Stop to restart

Grundfos SCALA1 and SCALA2 green light ring rotating while the pump is running

Rotating green: the pump is running

Grundfos SCALA1 and SCALA2 steady green light ring while the pump is powered on and resting

Steady green: powered on and resting (no water demand)

A red alarm is showing

A red alarm means the pump has detected a condition that requires attention. It does not automatically mean the pump is defective.

Grundfos SCALA1 control panel with flashing red alarm light

SCALA1 flashing red alarm

Grundfos SCALA2 control panel with flashing red alarm light

SCALA2 flashing red alarm

  • Check the water source, open valves, priming, inlet strainer/filter and possible air leaks on the inlet side.
  • If the alarm indicates leakage or repeated starts, check for dripping taps, running toilets, ice makers, irrigation or other water use.
  • SCALA2 has additional alarm indications, including pump blockage, power supply problems, temperature limits and pressure-related conditions. Match the exact symbol to the manual for your model.
  • Correct the likely cause before pressing Reset. If the same alarm returns after the water supply and inlet restrictions have been checked, take a photo of the panel and contact support.

SCALA2 alarm quick reference

Symbol What it means First thing to check
1Grundfos SCALA2 alarm symbol 1: Power supply problem Power supply problem: voltage outside the required range Outlet, breaker and supply voltage
2Grundfos SCALA2 alarm symbol 2: Pump cannot turn Pump cannot turn: pump or shaft may be blocked Contact support; do not dismantle the pump
3Grundfos SCALA2 alarm symbol 3: Possible leak Possible leak or repeated starting and stopping Close all taps and check plumbing for leaks
4Grundfos SCALA2 alarm symbol 4: Water shortage / dry running Water shortage / dry running Water supply, valves and priming
5Grundfos SCALA2 alarm symbol 5: Pressure limit / target problem Pressure too high, or the selected target cannot be reached Pressure setpoint, water supply and inlet restrictions
6Grundfos SCALA2 alarm symbol 6: Runtime limit reached Runtime limit reached: pump ran longer than permitted Leaks or water left running
7Grundfos SCALA2 alarm symbol 7: Temperature out of range Temperature out of range: pump or water too hot or too cold Pump location and water temperature

Important: Do not dismantle the pump or try to free an internal shaft unless the instructions for your exact model specifically direct you to do so. Contact support for help with blockage or repeated alarms.

The pump keeps starting, stopping or running with all taps closed

  • A small plumbing leak can cause a booster pump to restart. Check toilets, faucets, ice makers, humidifiers, irrigation, water treatment equipment and water heater relief discharge.
  • If you have an outlet shutoff valve and can operate it safely, close it briefly while observing the pump. If the pump stops and remains off, the cause is likely downstream in the house plumbing. Reopen the valve after the test. Never leave the system isolated unintentionally.
  • Debris in a non-return/check valve can allow pressure to bleed back and cause cycling. Cleaning may be needed; follow the model manual or ask a plumber or support for assistance.
  • SCALA1 has a leak-detection/anti-cycling function. If it stops because it detects repeated starts, investigate the leak or water use before resetting.
  • SCALA2: Check the built-in tank pre-charge as described below if the pump restarts soon after stopping.
Grundfos SCALA1 control panel with red leak-detection symbol lit

SCALA1 possible leak: close all taps and check for leaks

Grundfos SCALA1 control panel with steady yellow light showing an external stop

SCALA1 steady yellow: check the external switch and Grundfos GO schedule

Pressure or flow is weak, surging or fluctuating

  • Check that the source can provide enough water and that all valves are open.
  • Clean or replace a clogged inlet strainer or filter. A booster cannot compensate for an undersized supply line or inadequate water source.
  • Prime the pump and bleed air from the system by running the highest tap until flow is steady.
  • Inspect the inlet piping for kinks, restrictions, loose fittings or air leaks. Suction-side leaks can draw in air without necessarily leaking water outward.
  • SCALA2: The factory pressure setting is about 44 psi. If the supply cannot support the chosen setpoint, reducing the setpoint may improve stability. Do not assume a higher setting will always produce better flow.
  • SCALA1: Check whether the height of the highest tap and the demands of the installation are within the selected model's performance limits. Refer to the model data or contact support.
  • If pressure is still poor after these checks, the issue may be upstream supply capacity, pipe sizing or pump/application selection.

SCALA2 only: pressure fluctuates or the green pressure light flashes

SCALA2 has a small built-in pressure tank. Its air pre-charge should be set to 70% of the pressure setpoint and must never exceed the setpoint. Incorrect pre-charge can contribute to fluctuating pressure, frequent starts and noise.

  • To check or adjust it, stop the pump, unplug it, isolate the water supply and fully release water pressure before using a tire gauge at the air valve on top.
  • Use the pre-charge value for your selected setpoint from the current Grundfos manual or the label/guide supplied with the pump. At the factory setting of about 44 psi, the target is about 31 psi.
  • After adjustment, replace the valve cap, reopen the supply and restart. If you are unsure how to safely depressurize the system, ask a plumber or contact support.

A flashing green pressure light can indicate that SCALA2 has temporarily reduced its target because it cannot reach the selected pressure. Check for air, inlet restrictions and inadequate supply before assuming a pump fault.

Grundfos SCALA2 control panel with flashing green pressure light

The pump may have reduced its pressure target because it cannot reach the selected setting.

There is water under or around the pump

  • A small amount of moisture from the shaft seal area can occur during start-up while the seal faces become fully lubricated. Condensation can also form on a cold pump or pipe in a humid room.
  • Dry the pump and nearby pipes, then place a dry paper towel beneath the area to help locate the source. Check again later.
  • Water at a pipe connection may indicate a poorly seated gasket or incorrectly sealed adapter. Switch off and unplug the pump before checking connections; hand-tighten pump unions only.
  • A leak that grows, forms a steady stream or puddle, reaches electrical parts, or occurs with new noise or loss of pressure is not something to ignore. Switch off the pump and contact support.
  • Never remove covers or continue operating a pump if water is reaching electrical components.

The pump is noisy or vibrating

  • Gurgling or sputtering often points to air in the system. Re-prime if necessary and run the highest tap until flow is steady.
  • A gravelly sound can indicate inadequate water supply or a restricted inlet. Check the inlet valve, strainer, filter and pipework.
  • Vibration can travel through rigid pipes and walls. The pump should be securely mounted on a stable, level surface, and the piping should be supported. Flexible connectors may reduce transmitted vibration when correctly installed.
  • SCALA2: Incorrect tank pre-charge can contribute to noise and pressure fluctuations.
  • Stop and contact support if you hear grinding, scraping or metallic noise, or if the pump hums but does not start.

The water heater relief valve drips after installation

A booster pump with non-return valves can prevent heated water from expanding back toward the water main. This can raise pressure in a closed plumbing system and cause the water heater's temperature-and-pressure relief valve to discharge. It is a plumbing system issue, not necessarily a pump defect.

  • Have a qualified plumber check the thermal expansion control and expansion tank, if required, and verify that the system pressure is appropriate.
  • Never cap, plug or obstruct a water heater relief valve. If it continues discharging, arrange prompt professional service.

When to stop troubleshooting

Stop and contact support if you notice: a cracked housing; a leak that continues or reaches electrical parts; a burning smell or smoke; repeated breaker trips; shock or tingling; grinding or metallic noise; or an alarm that returns after basic supply, priming and filter checks. Do not continue operating the pump in these conditions.

Contact Fresh Water Systems before returning the pump

We can often help identify an installation or supply issue before you remove and return the pump. Please have the following ready:

  • Your Amazon or Fresh Water Systems order number
  • The exact model and voltage from the nameplate
  • A photo of the control panel with the indicator lights visible
  • A photo showing the pump and its inlet/outlet piping
  • A short description of the symptom, when it started and what you have already checked
  • If there is a leak or unusual noise, a short video can be especially helpful

Phone: (877) 930-7295 | Monday–Friday, 8 a.m.–7 p.m. Eastern

You can also contact us online.

Wondering if your pump is covered? Click here to view Grundfos warranty information.

FAQs: Grundfos SCALA troubleshooting

Why is my Grundfos SCALA2 showing a red light?

A red alarm means the pump has detected a condition that needs attention, such as not enough water, a leak, a blockage or a temperature or power issue. It doesn't automatically mean the pump is defective. Check the water supply, valves, priming and inlet filter, then match the symbol to your manual before pressing Reset.

Why does my SCALA2 keep turning on and off?

Frequent cycling is usually caused by a small leak or hidden water use, like a running toilet, ice maker or irrigation system. On the SCALA2, an incorrect tank pre-charge can also cause frequent starts. Debris in a check valve can let pressure bleed back as well.

What should the SCALA2 tank pre-charge be?

The air pre-charge should be 70% of your pressure setpoint and should never exceed it. At the factory setting of about 44 psi, that's about 31 psi. Always unplug the pump and release water pressure before checking it with a tire gauge.

What is the factory pressure setting on the SCALA2?

The SCALA2 ships with a setpoint of about 44 psi. You can adjust it with the up and down buttons on the control panel, but a higher setting won't always give you better flow if your water supply can't keep up.

Does the SCALA1 have a built-in pressure tank?

No. The SCALA2 has a small built-in pressure tank, but the SCALA1 does not.

How much water does it take to prime a SCALA pump?

If you're drawing water from a tank or well below the pump, fill the housing through the priming port with about 1.7 L (0.45 gal) of clean water. If the pump is connected to a pressurized supply, open the supply valve and let the housing fill.

Is it normal to see a little water under my new pump?

A small amount of moisture near the shaft seal can happen during start-up, and condensation can form in humid rooms. A leak that grows, forms a puddle or reaches electrical parts is not normal. Switch off the pump and contact support.

Why is my water heater relief valve dripping after installing a booster pump?

A booster pump's non-return valves can trap expanding hot water, raising pressure in your plumbing. This is a plumbing issue, not a pump defect. Have a plumber check your thermal expansion control, and never cap or plug a relief valve.

Check the basics first

A SCALA pump may be protecting itself from dry running, responding to a leak or reacting to a restricted water supply. Check the basics first, record the alarm indication, and contact Fresh Water Systems if the cause is not clear. Always follow the installation and operating instructions supplied with your exact pump.

¹ Standard GFCI outlets aren’t designed for the way SCALA pumps draw power and may trip, especially at start-up. Grundfos specifies Type B ground-fault protection where code requires it. Have a licensed electrician confirm what your local code requires.

This guide is a troubleshooting aid, not a substitute for the current Grundfos Installation and Operating Instructions for your specific SCALA1 or SCALA2 model. Use the model manual for alarm code interpretation, electrical requirements, performance limits and any service procedure.